Elevista Lift Battery Backup

No. 1 lift backup in India!

lift-backup-india-lift-inverter-lift-ups

Elevista is a series of lift backups compatible with all types of lifts. It is the only lift backup in the market with inbuilt Emergency Rescue Technology, that ensures the passengers never get stranded inside the lift cabin. While manufacturing the elevator backup system, factors such as the duration of a common power cut, capacity of the lift motor, type of elevator, whether it would be used in a residential or commercial area, etc. are taken into consideration. So with our inhouse research and development we have come up with the very innovative power backup solution for lifts and elevators.

Not all power back up systems are created equal. We have experimented with numerous different ways to ensure that you never get stranded if you have brownouts or power quality issues in your area. A typical commercial UPS is not designed to handle motor loads, and therefore we had to design custom backup systems to meet the reliability requirements of the market. Our backup consists of technologi y advanced features like floor level sensing, advanced rescue technology, mains stability sense, wireless display, etc. which have helped us to retain number one position in the market.

lift-backup-india-lift-inverter-lift-ups

Lift backup v/s Emergency Rescue Device/ ERD/ ARD:

Emergency rescue device (also known as ERD/ ARD) runs the lift for short duration like 30 seconds during an event of a power failure, for the purpose of evacuation of the passengers inside the lift. Whereas lift backup is a complete backup solution which runs the lift during a power failure for 2 to 8 hours depending on the capacity of the batteries.

In case of AUTOMATIC rescue device once the evacuation of the passengers is done it shuts down, you cannot use the lift until the power resumes. Whereas in case of lift backup you can continue using the lift just like you do in the presence of grid power.

lift-backup-india-lift-inverter-lift-ups

Lift backup v/s desiel generator:

Diesel generator which have to run as per full load conditions thereby resulting in substantial fuel expenses, lift backup can run on partial load. The efficiency of generators reduces when running partial loads resulting in more consumption of the fuel and reduced life of the generator, whereas lift backup operate with same efficiency at all load settings and, in fact, provide higher backup time at partial loads.

Pollution level of the environment is risen and the air quality of the surroundings is reduced as a diesel generator emits hazardous smoke. Lift backup on the other hand are more eco-friendly and produce no hazardous smoke, while efficiently powering high load applications. In case of lift backup, no external source of energy is required to operate. It stores the power when there are normal power conditions and once there is power outage, the lift backup acts as an auxiliary power source. Lift backup, compared to there diesel-generators counterpart is more efficient, clean and reliable. These do not cause noise or environmental pollution.

Working of lift backup in different modes:

lift-backup-india-lift-inverter-lift-ups

Worknig of lift backup in presence of grid supply:

In the presence of grid supply, the lift backup bypasses the input three phase supply to the lift panel and simultaneously charges the batteries. The inbuilt battery charger charges the batteries in 5 different stages thereby increasing batteries lifespan.

Elevista has inbuilt single phasing preventer which constantly reads input three phase supply voltage. Failure of any phase or whenever any phase voltage goes high or low - exceeding the set range the UPS is shifted to inverter mode.

lift-backup-india-lift-inverter-lift-ups

Working of lift backup during grid supply failure-

In the case of power grid failure, that means when any of the three phases is absent or low, the inverter mode is automati y turned on and the lift or elevator is fed with the three phase supply generated by the inverter using battery power.

When the grid power is resumed the inverter mode is switched off automati y and the mains mode and charging of the batteries is resumed.

lift-backup-india-lift-inverter-lift-ups

Worknig of Emergency Rescue Technology:

We have developed the Emergency Rescue Technology which is an automatic elevator evacuation program designed for lift backup. This technology is also known as ARD - Advanced rescue device.

With this technology the lift backup is not shut down even in case of battery low condition when the lift is in between the floors. Upon opening the doors, the trapped passengers shall exit and the lift backup will shut down to prevent any further battery drain until the power grid is resumed. When power grid resumes, the lift backup will automati y switch over to the mains mode.

Salient features of elevista lift backup

lift-backup-india-lift-inverter-lift-ups

Digital Signal Processor Technology

The DSP technology ensures high speed operation of the lift backup and the purest sinewave output

Emergency Rescue Technology

ERT ensures the passengers are never trapped inside the lift during battery low condition

Inbuilt Single Phase Preventor

In the presence of grid supply Single Phasing Preventor ensures proper three phases go to the lift panel

5 Stage Battery Charger

The intelligent 5 stage battery charging increases battery life

Bypass Switch and MCB Protection

To make bypassing the Lift Backup easy - a bypass switch and MCB is provided

Elevista ADD ON features

lift-backup-india-lift-inverter-lift-ups

Twin Tower Solution

Elevista lift backup can be used for two lifts using a changeover panel. After the failure of grid supply the change over panel runs one lift. When the lift is reached to the ground it is shut down and the other lift is turned on and it continues to run it until the grid power supply is resumed.

Wireless Display

A wireless display can be installed inside the lift cabin. It shows if the lift is running on UPS mode or Mains mode. It also shows battery percentage.

Extra Load Output

Extra load single phase feature can be added to the Elevista lift backup, therefore there is no need to install separate inverter for passage lights.

lift-backup-india-lift-inverter-lift-ups

Single Phase Input

Three phase supply is not present in some places, therefore custom solution is needed. Elevista lift backup is customised so that it takes single phase input and supplies three phase output to run the lift.

GSM Based Alerts

For township projects the lift backup can be fitted with the GSM modem so that it sends alerts by SMS on the mobile phones of the concerned persons of each wing. Alerts like lift running on Mains or UPS, Phase failure, Single phasing or Battery status etc. are sent via sms.

Run Lift on Solar Power

Elevista lift backup can be fitted with solar modules to run the lift on solar power. It is useful where power grid failure is frequent or unstable.

Our Lift Backup Installations

elevista_lift_backup_india_lift_inverter_lift_ups
Lift backup installed in India

Lift backup in India

elevista_lift_backup_Nashik_lift_inverter_lift_ups
Lift backup installed in Nashik

Lift backup in Nashik

elevista_lift_backup_Mumbai_lift_inverter_lift_ups
Lift backup installed in Mumbai

Lift backup in Mumbai

elevista_lift_backup_Pune_lift_inverter_lift_ups
Lift backup installed in Pune

Lift backup in Pune

elevista_lift_backup_Kolhapur_lift_inverter_lift_ups
Lift backup installed in Kolhapur

Lift backup in Kolhapur

elevista_lift_backup_Solapur_lift_inverter_lift_ups
Lift backup installed in Solapur

Lift backup in Solapur

elevista_lift_backup_Pimpri-Chinchwad_lift_inverter_lift_ups
Lift backup installed in Pimpri-Chinchwad

Lift backup in Pimpri-Chinchwad

elevista_lift_backup_Thane_lift_inverter_lift_ups
Lift backup installed in Thane

Lift backup in Thane

elevista_lift_backup_Nagpur_lift_inverter_lift_ups
Lift backup installed in Nagpur

Lift backup in Nagpur

elevista_lift_backup_Kalyan_lift_inverter_lift_ups
Lift backup installed in Kalyan

Lift backup in Kalyan

elevista_lift_backup_Jalgaon_lift_inverter_lift_ups
Lift backup installed in Jalgaon

Lift backup in Jalgaon

elevista_lift_backup_Aurangabad_lift_inverter_lift_ups
Lift backup installed in Aurangabad

Lift backup in Aurangabad

elevista_lift_backup_Bhiwandi_lift_inverter_lift_ups
Lift backup installed in Bhiwandi

Lift backup in Bhiwandi

elevista_lift_backup_Malegaon_lift_inverter_lift_ups
Lift backup installed in Malegaon

Lift backup in Malegaon

elevista_lift_backup_Ahmedabad_lift_inverter_lift_ups
Lift backup installed in Ahmedabad

Lift backup in Ahmedabad

elevista_lift_backup_Surat_lift_inverter_lift_ups
Lift backup installed in Surat

Lift backup in Surat

elevista_lift_backup_Vadodara_lift_inverter_lift_ups
Lift backup installed in Vadodara

Lift backup in Vadodara

Specifications of Elevista Lift Backup :

Model Elevista Lift Backup (6 KVA to 25 KVA )
Technology IGBT
Input Voltage 230V /415 VAC (±15%)
Input Voltage Range 150 to 280 VAC P-N / 350 - 460 VAC P-P (±15%)
Input Frequency 50 Hz (±5%)
Charging Current 10 A max (±1%)
Output Frequency 50 Hz (±0.5%)
Output Voltage 250 VAC P-N / 415 VAC P-P (±3%)
Change Over Time 20 Seconds
Load power Factor 0.8 to 1 lagging
Inverter Efficiency >90%
Output Wave form Pure sinewave
Harmonic Distortion Less than 3% with linear load
Overload <105% continuous 105% to 200% for 30 Sec. >200% Inverter Trips
Indications Mains ON, Charging ON, Inverter ON, Battery Low, Overload
Audible Alarm Battery Low pre-alarm at 80% of discharge / in ARD mode
Protections Input single phasing / Battery under voltage / Output overload / Input MCB
Changeover Electro-mechanical / Contactor based / Static Switch
Backup time 1 Hour to 10 Hours
Operating Temperature 0 °C to 55 °C
Humidity Max 95%, Non-condensing
Cooling Forced air cooling with fan
Acoustic Noise Less than 45 dB at 1 Meter

Frequently Asked Questions

We understand that you may have many doubts and questions about the type and specifications of the product. Our experts have tried to answer as many FAQs as possible. If you don't find your questions you can email your questions to us. Please let us know if you find the FAQ helpful.

Different models of Elevista Lift Backup :

MODEL CAPACITY BATTERY TOPOLOGY ADD-ON
ELT6K72 6 KVA 72 VDC 3 Phase in 3 Phase out MCB-Bypass-Inbuilt ARD
ELT8K72 8 KVA 72 VDC 3 Phase in 3 Phase out MCB-Bypass-Inbuilt ARD
ELT8K96 8 KVA 96 VDC 3 Phase in 3 Phase out MCB-Bypass-Inbuilt ARD
ELT8K120 8 KVA 120 VDC 3 Phase in 3 Phase out MCB-Bypass-Inbuilt ARD
ELT10K120 10 KVA 120 VDC 3 Phase in 3 Phase out MCB-Bypass-Inbuilt ARD
ELT15K180 15 KVA 180 VDC 3 Phase in 3 Phase out MCB-Bypass-Inbuilt ARD
ELT20K240 20 KVA 240 VDC 3 Phase in 3 Phase out MCB-Bypass-Inbuilt ARD
ELT25K360 25 KVA 360 VDC 3 Phase in 3 Phase out MCB-Bypass-Inbuilt ARD

24X7 Support

For support reach out to us right here and we'll get back to you as soon as we can!